8 – Other functions
Setting the termination for reference
input connectors
Set the termination for each input connector according to the
wiring.
Make these settings on the
TERMINATION
page.
1. Press the MENU button repeatedly to open the
TERMI-
NATION
menu page, and turn the MULTI JOG dial to select
the input connector for which you want to set the termi-
nation.
VIDEO selected
2. Press the MULTI JOG dial to open the
TERMINATION
XXX
screen (“ XXX” is the name of the input connector).
TERMINATION VIDEO
screen open
3. Turn the MULTI JOG dial to set the termination for the input
connector.
Options
Video clock input connector: 75ohm (default), OPEN
Word clock input connector: 75ohm (default), 50ohm,
OPEN
GPS signal input connector: 50ohm (default), OPEN
4. Press the MULTI JOG dial to confirm the selection and return
to the menu.
Setting the levels of the word clock
outputs
You can change the output levels of the word clock outputs.
Change these levels on the
WORD OUT LEVEL
page.
1. Press the MENU button repeatedly to open the
WORD
OUT LEVEL
menu page, and turn the MULTI JOG dial to
select the word clock output connectors for which you want
to set the level.
1/2 selected
2. Press the MULTI JOG dial to open the
WORD OUT
LEVEL 1/2
screen.
WORD OUT LEVEL 1/2
screen open
3. Turn the MULTI JOG dial to set the output level of the word
clock output connectors.
Options: 1.0V, 1.5V, 2.0V, 2.5V (default), 3.0V, 3.5V
4. Press the MULTI JOG dial to confirm the selection and return
to the menu.
Restoring factory default settings
You can restore the various settings saved in this unit’s backup
memory to their factory defaults.
Do this from the
UTILITY 1
page.
See “Default setting values list” on page 25 for the settings
when the unit is shipped new from the factory.
NOTE
The
STARTUP
item setting cannot be restored to the
factory default.
1. Press the MENU button repeatedly to open the
UTILITY
1
menu page, and turn the MULTI JOG dial to select the
FACTORY PRESET
item.
2. Press the MULTI JOG dial to open the
FACTORY
PRESET
pop-up.
3. Press the MULTI JOG dial to execute, or press the EXIT/
CANCEL button to cancel.