2 – Names and functions of parts
Error information screen (button lit red)
When trouble occurs with the unit, the INFO button lights red.
Press it to show the following information about the trouble on
the display.
8
Display of errors occurring currently
Trouble that is occurring currently is shown one item per line.
Example of current error display
8
Display of errors that occurred previously
Trouble that occurred previously is shown one item per page.
When an error is being shown, press the EXIT/CANCEL button
to clear all errors previously displayed completely.
Example of error display
1 Order number
Numbers assigned to errors in the order of occurrence.
2 Error details
This shows the error code and signal affected as described
in the Overview of error codes table blow. (See “Overview of
error codes” on page 11.)
3 Signal with error
This shows the signal with which the error occurred.
4 Date and time of error
This shows when the error occurred.
5 Error result
This shows the result of the error.
6 Date and time of recovery
This shows when recovery from the error occurred.
7 Recovery details
This shows how recovery from the error occurred.
8 Results of recovery
This shows the results of recovery.
8
Overview of error codes
The error codes that appear on the
ERROR INFORMATION
screen are as follows.
Error code
shown
Error code explanation
Signal
affected by
error
Unlock
The operation reference signal
became unlocked, and the unit
switched to the secondary reference
clock or backup reference clock.
WORD A
WORD B
VIDEO A
VIDEO B
AES
No Signal
There is no operation reference
signal being input, so the unit
switched to the secondary reference
clock or backup reference clock.
WORD A
WORD B
VIDEO A
VIDEO B
AES
Chasing
Switching reference clock. (This is
not listed in the display of errors
occurring currently.)
WORD A
WORD B
VIDEO A
VIDEO B
AES
INTERNAL
Switched to*
Switched to another reference
clock.
WORD A
WORD B
VIDEO A
VIDEO B
AES
INTERNAL
Stop PWR
The power supply to the AC IN A
connector or AC IN B connector has
been interrupted.
POWER A
POWER B
*This only appears on the second page or later pages of the